Re: Mellanox (old Voltaire) ISR9024D-M recover flash area

$
0
0

CAUTION!

 

IF YOU HAVE NOT CONSOLE CABLE, DON'T COMMIT FACTORY DEFAULT COMMAND on any

other IB switch.

 

Basically ISR9024D-M has a factory default configuration (192.168.1.2).

If you commit factory default command on CLI, you can connect default ip

address 192.168.1.2.

 

But another switches(Not ISR9024D-M) have default configuration DHCP for

management ethernet port.

 

If you want run the printenv command you must have a serial console cable.

 

I'm attache a normal ISR9024D-M boot log.

It was captured via console cable only.

 

You can run the printenv command in PPC-Boot console via serial console

cable.

 

 

 

.

.

.

PPCBoot 1.1.6 (Nov 16 2004 - 08:21:51)

 

CPU: IBM PowerPC 440 Rev. C

Board: Artesyn Technologies PM/PPC-440gp

Artesyn Monitor Version 1.5.0

VCO: 800 MHz

CPU: 400 MHz

PLB: 133 MHz

OPB: 66 MHz

EPB: 66 MHz

I2C: ready

DRAM: ECC Init ....Done 128 MB

FLASH: 64 MB

 

Initializing board as Monarch....

 

Scanning for PCI devices....

Scanning PCI devices on bus 0

LOCALE VEND DEV REV BASE0 BASE1 BASE2 BASE3 BASE4 BASE5