CAUTION!
IF YOU HAVE NOT CONSOLE CABLE, DON'T COMMIT FACTORY DEFAULT COMMAND on any
other IB switch.
Basically ISR9024D-M has a factory default configuration (192.168.1.2).
If you commit factory default command on CLI, you can connect default ip
address 192.168.1.2.
But another switches(Not ISR9024D-M) have default configuration DHCP for
management ethernet port.
If you want run the printenv command you must have a serial console cable.
I'm attache a normal ISR9024D-M boot log.
It was captured via console cable only.
You can run the printenv command in PPC-Boot console via serial console
cable.
.
.
.
PPCBoot 1.1.6 (Nov 16 2004 - 08:21:51)
CPU: IBM PowerPC 440 Rev. C
Board: Artesyn Technologies PM/PPC-440gp
Artesyn Monitor Version 1.5.0
VCO: 800 MHz
CPU: 400 MHz
PLB: 133 MHz
OPB: 66 MHz
EPB: 66 MHz
I2C: ready
DRAM: ECC Init ....Done 128 MB
FLASH: 64 MB
Initializing board as Monarch....
Scanning for PCI devices....
Scanning PCI devices on bus 0
LOCALE VEND DEV REV BASE0 BASE1 BASE2 BASE3 BASE4 BASE5